Page tree


StatusIn progress
Version

0.1

Descriptions:

Termdescription typeLanguage/acceptabilityLanguage/acceptabilityCase significance

[isotope] brachytherapy to [body structure] (procedure)

FSNus:Pgb:Pci

[isotope] brachytherapy to [body structure]

PTus:Pgb:Pci

example: 

700357007 |Radium 223 brachytherapy (procedure)|

Concept model:

Attribute group cardinalityAttribute cardinality

Attribute cardinality

in role group

AttributeValue
0..01..1
0..1
0..1
1..1
1..1

0..1

1..1

0..1

0..1

0..1

0..1


1..1

1..1

0..1

0..1

Definition status:  


900000000000073002 |Defined (core metadata concept)|

Applies to: 

<<  152198000 |Brachytherapy (procedure)|  MINUS (<<  228660009 |Contact therapy (procedure)|   OR (<<  152198000 |Brachytherapy (procedure)|  :   363703001 |Has intent (attribute)|   = <<  429892002 |Guidance intent (qualifier value)|  )) 'Pure' brachytherapy excluding contact therapy, guided procedures

Template language:

71388002 |Procedure (procedure)|
  [[~0..1]] {[[~0..1]] 
363702006 |Has focus (attribute)|  = [[+id(<<  404684003 |Clinical finding (finding)| ) ]] } 
  [[~1..1]] { 
    [[~1..1]] 
260686004 |Method (attribute)|  =  129445006 |Administration - action (qualifier value)|
    [[~0..1]] [[+id(< 
363704007 |Procedure site (attribute)|  ) @null]] = [[+id(<<  442083009 |Anatomical or acquired body structure (body structure)| )]], 
    [[~1..1]] 
424244007 |Using energy (attribute)|  = [[+id(<<  125576007 |Ionizing radiation (physical force)| ) ]], 
    [[~0..1]] 
424226004 |Using device (attribute)|  = [[+id(<<  466194000 |External beam radiation therapy radionuclide system (physical object)|  OR <<  706285003 |Accelerator system (physical object)|  )]], 
    [[~0..1]] 
424361007 |Using substance (attribute)|  =  [[+id(<<  89457008 |Radioactive isotope (substance)| or <<  285322002 |Subatomic particle (substance)|  or << 2141009 ) ]], 
    [[~0..1]] 
363700003 |Direct morphology (attribute)|  = [[+id(<<  49755003 |Morphologically abnormal structure (morphologic abnormality)| ) ]], 
    [[~0..1]] 
363703001 |Has intent (attribute)|  = [[+id(<  363675004 |Intents (nature of procedure values) (qualifier value)|  )]] },
  [[~1..1]] { 
    [[~1..1]] 
260686004 |Method (attribute)|  =  [[+id( <<  129336009 |Implantation - action (qualifier value)|   OR  <<  257867005 |Insertion - action (qualifier value)|  )]], 
    [[~1..1]]  
363699004 |Direct device (attribute)|   = [[+id(<<   371792008 |Brachytherapy device (physical object)|  )]],
    [[~0..1]]  
405814001 |Procedure site - Indirect (attribute)|   = [[+id(<  91723000 |Anatomical structure (body structure)|  )]],
    [[~0..1]]  
260507000 |Access (attribute)|   = [[+id(<   309795001 |Surgical access values (qualifier value)|  )]] }

Link to the misaligned concept report:

https://docs.google.com/spreadsheets/d/1kxLIehpEjVrAT4Ge4s8SzN1iIODkYeQwK1qVfOnYYr4/edit?gid=0#gid=0

Rules for description generation: 

  1. Apply General rules for generating descriptions for templates;
  2. Apply Enhancements for the Template Language.

JIRA ticket:



UML diagram:

UML diagram of radiotherapy procedures