Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Page properties


Version in PROD
StatusIn progressReady for implementation
Version

0.4

1.0


Descriptions:

Termdescription typeLanguage/acceptabilityLanguage/acceptabilityCase significance
[Access] [biopsy device] biopsy of [morphology] of [body structure] using [imaging] guidance (procedure)FSNus:Pgb:Pci
[Imaging] guided [access] [biopsy device] biopsy of [morphology] of [body structure]PTus:Pgb:Pci
[Access] [biopsy device] biopsy of [morphology] of [body structure] using [imaging] guidanceSYNus:Agb:Aci

Example: 16446481000119106 |Percutaneous core needle biopsy of thyroid using ultrasonographic guidance (procedure)|


Concept model: 

Attribute Group CardinalityAttribute Cardinality

Attribute in Group Cardinality

AttributeValue
0..01..1


Scg expression
116680003|Is a (attribute)|



Scg expression
71388002 |Procedure (procedure)|


1..2
0..1


Scg expression
260507000 |Access (attribute)|



Scg expression
< 309795001 |Surgical access values (qualifier value)|



1..1


Scg expression
260686004 |Method (attribute)|


[imaging]

Scg expression
<< 360037004 |Imaging - action (qualifier value)| 



0..1


Scg expression
405813007 |Procedure site - Direct (attribute)|



Scg expression
< 442083009 |Anatomical or acquired body structure (body structure)|



1..1


Scg expression
363703001 |Has intent (attribute)|



Scg expression
429892002 |Guidance intent (qualifier value)|



0..1


Scg expression
424361007 |Using substance (attribute)|



Scg expression
385420005 |Contrast media (substance)|



0..1


Scg expression
424226004 |Using device (attribute)|



Scg expression
<<262182009 |Stereotactic device (physical object)|



0..1


Scg expression
425391005 |Using access device (attribute)|



Scg expression
<<49062001 |Device (physical object)|


1..2
0..1


Scg expression
260507000 |Access (attribute)|


[Access]

Scg expression
< 309795001 |Surgical access values (qualifier value)|



1..1


Scg expression
260686004 |Method (attribute)|



Scg expression
<< 129314006 |Biopsy - action (qualifier value)|



0..1


Scg expression
405813007 |Procedure site - Direct (attribute)|


[body structure]

Scg expression
< 442083009 |Anatomical or acquired body structure (body structure)|



0..1


Scg expression
363700003 |Direct morphology (attribute)|


[morphology]

Scg expression
<<  49755003 |Morphologically abnormal structure (morphologic abnormality)| 



0..1


Scg expression
424226004 |Using device (attribute)|


[biopsy device]

Scg expression
<< 118377000 |Biopsy needle, device (physical object)| OR <<22566001 |Cytology brush, device (physical object)| OR <<360237009 |Vacuum aspirator (physical object)|



0..1


Scg expression
425391005 |Using access device (attribute)|



Scg expression
<<49062001 |Device (physical object)|


Definition status:  


Scg expression
900000000000073002 |Sufficiently defined by necessary conditions definition status (core metadata concept)|


Applies To:

Concept
t<< 71388002 |Procedure (procedure)| : 260686004 |Method (attribute)| = << 129314006 |Biopsy - action (qualifier value)| and 260686004 |Method (attribute)| = << 360037004 |Imaging - action (qualifier value)|

Template language: 

Scg expression
71388002 |Procedure (procedure)| : 
[[~1..2]] { 
[[~0..1]] 260507000 |Access (attribute)| = [[+id ( < 309795001 |Surgical access values (qualifier value)| ) @Accessaction1]],[[~1..1]] 260686004 |Method (attribute)| = [[ +id ( << 360037004 |Imaging - action (qualifier value)|) @Imagingaction ]], 
[[~0..1]] 405813007 |Procedure site - Direct (attribute)| = [[ +id (< 442083009 |Anatomical or acquired body structure (body structure)|) @Bodystructure1 ]],
[[~1..1]] 363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)|,[[~0..1]] 424361007 |Using substance (attribute)| = 385420005 |Contrast media (substance)|, [[~0..1]] 424226004 |Using device (attribute)| = [[ +id ( <<262182009 |Stereotactic device (physical object)|) @Usingdevice ]],[[~0..1]] 425391005 |Using access device (attribute)| = [[ +id ( <<49062001 |Device (physical object)|) @Usingaccessdevice1 ]] },
[[~1..2]] { 
[[~0..1]] 260507000 |Access (attribute)| = [[+id ( < 309795001 |Surgical access values (qualifier value)| ) @Accessaction2]],
[[~1..1]] 260686004 |Method (attribute)| = [[+id ( << 129314006 |Biopsy - action (qualifier value)| ) @Biopsyaction]],
[[~0..1]] 405813007 |Procedure site - Direct (attribute)| = [[+id (< 442083009 |Anatomical or acquired body structure|) @Bodystructure2 ]],
[[~0..1]] 363700003 |Direct morphology (attribute)| = [[+id(<< 49755003 |Morphologically abnormal structure (morphologic abnormality)| ) @Morphology]], 
[[~0..1]] 424226004 |Using device (attribute)| = [[+id(<< 118377000 |Biopsy needle, device (physical object)| OR <<22566001 |Cytology brush, device (physical object)| OR <<360237009 |Vacuum aspirator (physical object)|) @Biopsydevice]],[[~0..1]] 425391005 |Using access device (attribute)| = [[ +id ( <<49062001 |Device (physical object)|) @Usingaccessdevice2 ]] }

Link to the misaligned concept report:

https://docs.google.com/spreadsheets/d/1e13y7cb48bgKjjZKK-s-bJrKwty6zmCir9fA0P5oLx0/edit?usp=sharing

Rules for description generation: 

  1. Apply General rules for generating descriptions for templates;
  2. Apply Enhancements for the Template Language;
  3. For magnetic resonance imaging guidance, the naming should be FSN: [Access] [biopsy needle] biopsy of [morphology] of [body structure] using magnetic resonance imaging guidance (procedure), PT: MRI guided [access] [biopsy needle] biopsy of [morphology] of [body structure] - This PT should use case significance CS CS, SYN: [Access] [biopsy needle] biopsy of [morphology] of [body structure] using magnetic resonance imaging guidance.
  4. For computed tomography guidance, the naming should be FSN: [Access] [biopsy needle] biopsy of [morphology] of [body structure] using computed tomography guidance (procedure), PT: CT guided [access] [biopsy needle] biopsy of [morphology] of [body structure] - This PT should use case significance CS CS, SYN: [Access] [biopsy needle] biopsy of [morphology] of [body structure] using computed tomography guidance.
  5. For ultrasonography guidance, the naming should be FSN: [Access] [biopsy needle] biopsy of [morphology] of [body structure] using ultrasonographic guidance (procedure), PT: Ultrasonography guided [access] [biopsy needle] biopsy of [morphology] of [body structure], SYN: [Access] [biopsy needle] biopsy of [morphology] of [body structure] using ultrasonographic guidance, SYN: [Access] [biopsy needle] biopsy of [morphology] of [body structure] using ultrasound guidance.
  6. For percutaneous fine needle aspiration biopsy, the descriptions should follow this example format: FSN: Percutaneous fine needle aspiration biopsy of X (procedure), PT: Percutaneous fine needle aspiration biopsy of X, SYN: Percutaneous fine needle aspiration of X, SYN: Percutaneous fine needle biopsy of X. Imaging guidance should be inserted in descriptions as appropriate.

JIRA ticket:

Jira
serverIHTSDO JIRA
serverIdb202d822-d767-33be-b234-fec5accd5d8c
keyQI-940
Jira
serverIHTSDO JIRA
serverIdb202d822-d767-33be-b234-fec5accd5d8c
keyQI-941

Jira
serverIHTSDO JIRA
serverIdb202d822-d767-33be-b234-fec5accd5d8c
keyINFRA-8933