Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Page properties


StatusIn progress
Version

0.1


Descriptions:

Termdescription typeLanguage/acceptabilityLanguage/acceptabilityCase significance

Catheterization of [body structure] (procedure)

FSNus:Pgb:Pci
Catheterization of [body structure] PTus:Pgb:Pci
Insertion of cannula into [body structure] Aus:Pgb:Pci

Example: 449181007 |Insertion of cannula into pancreatic duct (procedure)|

Concept model:

Attribute Group CardinalityAttribute cardinality

Attribute in Group Cardinality

AttributeValue
0..01..10..0


Scg expression
116680003|Is a (attribute)|



Scg expression
71388002|Procedure (procedure)|


0..11..11..1


Scg expression
260686004|Method (attribute)|



Scg expression
<< 257867005 |Insertion - action (qualifier value)|  


0..1


Scg expression
405814001 |Procedure site - Indirect (attribute)|



Scg expression
[body structure] <  442083009 |Anatomical or acquired body structure (body structure)|


0..1


Scg expression
405816004 |Procedure morphology (attribute)|



Scg expression
[morphologic abnormality] < 49755003 |Morphologically abnormal structure (morphologic abnormality)|


1..1


Scg expression
363699004 |Direct device (attribute)|



Scg expression
[device] << 12150006 |Cannula, device (physical object)| OR << 19923001 |Catheter, device (physical object)|


0..1


Scg expression
363710007 |Indirect device (attribute)|



Scg expression
[device] << 49062001 |Device (physical object)|


0..1


Scg expression
260507000 |Access (attribute)|



Scg expression
[access] < 309795001 |Surgical access values (qualifier value)|


0..1


Scg expression
424876005 |Surgical approach (attribute)|



Scg expression
[approach] < 103379005 |Procedural approach (qualifier value)|


0..1


Scg expression
425391005 |Using access device (attribute)|



Scg expression
<< 37270008 |Endoscope, device (physical object)|


0..10..11..1


Scg expression
260686004|Method (attribute)|



Scg expression
[imaging] <<  360037004 |Imaging - action (qualifier value)|  


0..1


Scg expression
405813007 |Procedure site - Direct (attribute)|



Scg expression
[body structure] <  442083009 |Anatomical or acquired body structure (body structure)|


1..1


Scg expression
363703001 |Has intent (attribute)|



Scg expression
429892002 |Guidance intent (qualifier value)|


0..1


Scg expression
424361007 |Using substance (attribute)|



Scg expression
[contrast] << 385420005 |Contrast media (substance)|




0..1


Scg expression
363699004 |Direct device (attribute)|



Scg expression
<< 260787004 |Physical object (physical object)| 




0..1


Scg expression
363700003 |Direct morphology (attribute)|



Scg expression
49755003 |Morphologically abnormal structure (morphologic abnormality)|


Definition status:  



Scg expression
900000000000073002|Defined (core metadata concept)|


Applies to:

Scg expression
<< 782901001 |Insertion procedure (procedure)|


Template language:


Scg expression
71388002 |Procedure (procedure)|  :  
[[~1..1]]{ 
[[~1..1]]  260686004 |Method (attribute)|  = [[+id (<< 257867005 |Insertion - action (qualifier value)| )]], 
[[~0..1]]  405814001 |Procedure site - Indirect (attribute)|  = [[+id (< 442083009 |Anatomical or acquired body structure (body structure)|  ) @bodyStructure]],
[[~0..1]]  405816004 |Procedure morphology (attribute)| = [[+id (< 49755003 |Morphologically abnormal structure (morphologic abnormality)| ) @morphology]], 
[[~1..1]]  363699004 |Direct device (attribute)|  = [[+id (<< 12150006 |Cannula, device (physical object)|  ) OR (<<19923001 |Catheter, device (physical object)| ) @device]],
[[~0..1]]  363710007 |Indirect device (attribute)|  = [[+id (<< 49062001 |Device (physical object)|  )]], 
[[~0..1]]  260507000 |Access (attribute)| = [[+id (<< 309795001 |Surgical access values (qualifier value)| ) @access]],  
[[~0..1]]  424876005 |Surgical approach (attribute)| = [[+id (<< 103379005 |Procedural approach (qualifier value)| ) @approach]], 
[[~0..1]]  425391005 |Using access device (attribute)| = [[+id (<< 37270008 |Endoscope, device (physical object)| )]]
},
[[~0..1]]{  
[[~1..1]]  260686004 |Method (attribute)|  = [[+id(<< 360037004 |Imaging - action (qualifier value)|  ) @imaging]],
[[~0..1]]  405813007 |Procedure site - Direct (attribute)|  = [[+id(< 442083009 |Anatomical or acquired body structure (body structure)|  ) @bodyStructure]],
[[~1..1]]  363703001 |Has intent (attribute)|  =  429892002 |Guidance intent (qualifier value)|,
[[~0..1]]  363699004 |Direct device (attribute)|  = [[+id (<< 260787004 |Physical object (physical object)|  )]],
[[~0..1]]  363700003 |Direct morphology (attribute)|  = [[+id (<< 49755003 |Morphologically abnormal structure (morphologic abnormality)|  )]],    
[[~0..1]]  424361007 |Using substance (attribute)|  = [[+id(<< 385420005 |Contrast media (substance)|  ) @contrast]]}   


Link to the misaligned concept report:


Rules for description generation: 

  1. Apply General rules for generating descriptions for templates;
  2. Apply Enhancements for the Template Language;

JIRA ticket:


Jira
serverIHTSDO JIRA
serverIdb202d822-d767-33be-b234-fec5accd5d8c
keyQI-1131