Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Page properties


StatusFor review
Version

1.0


Descriptions:

Termdescription typeLanguage/acceptabilityLanguage/acceptabilityCase significance
[Action] of [morphologic abnormality] of [body structure] by diathermy (procedure)FSNus:Pgb:Pci

[Action] of [morphologic abnormality] of [body structure] by diathermy

PTus:Pgb:Pci

Example: 

25444001 |Destruction of lesion of choroid by diathermy (procedure)|

1287893003 |Repair of retinal tear by diathermy (procedure)|

Concept model:

Attribute Group CardinalityAttribute cardinality

Attribute in Group Cardinality

AttributeValue
0..01..10..0


Scg expression
116680003|Is a (attribute)|



Scg expression
71388002 |Procedure (procedure)|


0..11..11..1


Scg expression
260686004|Method (attribute)|



Scg expression
[action] << 129382001 |Destruction - action (qualifier value)| OR << 257903006 |Repair - action (qualifier value)| OR << Fixation - action (qualifier value)


0..1


Scg expression
405813007 |Procedure site - Direct (attribute)|



Scg expression
[body structure] <  442083009 |Anatomical or acquired body structure (body structure)|


0..1


Scg expression
363700003 |Direct morphology (attribute)|



Scg expression
[morphologic abnormality] <  49755003 |Morphologically abnormal structure (morphologic abnormality)|


1..1


Scg expression
424226004 |Using device (attribute)|



Scg expression
[device] 705760000 |Electrosurgical diathermy system (physical object)|


1..1


Scg expression
424244007 |Using energy (attribute)|



Scg expression
18213006 |Electricity (physical force)|


0..10..11..1


Scg expression
363702006 |Has focus (attribute)|



Scg expression
<< 404684003 |Clinical finding (finding)| OR << 71388002 |Procedure (procedure)|


Definition status:  



Scg expression
900000000000073002|Defined (core metadata concept)|

...

Scg expression
71388002 |Procedure (procedure)|  :  
[[~1..1]]{ 
[[~1..1]]  260686004 |Method (attribute)|  = [[+id (<< 129382001 |Destruction - action (qualifier value)| OR << 257903006 |Repair - action (qualifier value)| OR << Fixation - action (qualifier value) ) @action]], 
[[~0..1]]  405813007 |Procedure site - Direct (attribute)|  = [[+id (< 442083009 |Anatomical or acquired body structure (body structure)|  ) @bodyStructure]],
[[~0..1]]  363700003 |Direct morphology (attribute)| = [[+id (<  49755003 |Morphologically abnormal structure (morphologic abnormality)| ) @morphologicalabnormality]],
[[~1..1]]  424226004 |Using device (attribute)|  = [[+id (705760000 |Electrosurgical diathermy system (physical object)|  ) @device]],
[[~1..1]]  424244007 |Using energy (attribute)| = [[+id (18213006 |Electricity (physical force)| ) @physicalforce]]},
[[~0..1]]{
[[~1..1]] 363702006 |Has focus (attribute)| = [[+id (<< 404684003 |Clinical finding (finding)| OR << 71388002 |Procedure (procedure)| )]]}

 

...