Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Page properties


StatusIn progress
Version

0.1


Descriptions:

PTPP
Termdescription typeLanguage/acceptabilityLanguage/acceptabilityCase significance

[Access] Insertion of cannula into into [body structure] (procedure)

FSNus:Pgb:Pci

[Access] Cannulation of [body structure] (procedure)

PTus:Pgb:Pci
[Access] Insertion of cannula into [body structure] Aus:Agb:Aci

Example: 449181007 |Insertion of cannula into pancreatic duct (procedure)|

Concept model:

[body structure]
Attribute Group CardinalityAttribute cardinality

Attribute in Group Cardinality

AttributeValue
0..01..10..0


Scg expression
116680003|Is a (attribute)|



Scg expression
71388002|Procedure (procedure)|


0..1
1..1


Scg expression
260686004|Method (attribute)|



Scg expression
<< 257867005 |Insertion - action (qualifier value)|  


0..1


Scg expression
405813007 |Procedure site - Direct (attribute)|



Scg expression
<  442083009 |Anatomical or acquired body structure (body structure)|


0..1


Scg expression
363699004 |Direct device (attribute)|



Scg expression
<< 12150006 |Cannula, device (physical object)|


0..1


Scg expression
363699004 |Direct device (attribute)|



Scg expression
<< 12150006 |Cannula, device (physical object)|


0..1
1..1


Scg expression
260686004|Method (attribute)|



Scg expression
<< 257867005 |Insertion - action (qualifier value)|



0..1


Scg expression
405814001 |Procedure site - Indirect (attribute)|



Scg expression
< 442083009 |Anatomical or acquired body structure (body structure)|



1..1


Scg expression
363699004 |Direct device (attribute)|



Scg expression
<< 12150006 |Cannula, device (physical object)|



0..1


Scg expression
260507000 |Access (attribute)|



Scg expression
[access] < 309795001 |Surgical access values (qualifier value)|


Definition status:  



Scg expression
900000000000073002|Defined (core metadata concept)|


Applies to:

Scg expression
<< 42825003 |Cannulation (procedure)|


Template language:


Scg expression
71388002 |Procedure (procedure)|  :  
[[~1..1]]{ 
[[~1..1]]  260686004 |Method (attribute)|  = [[+id (<< 257867005 |Insertion - action (qualifier value)| )]], 
[[~0..1]]  405814001 |Procedure site - Indirect (attribute)|  = [[+id (< 442083009 |Anatomical or acquired body structure (body structure)|  ) @bodyStructure]], 
[[~1..1]]  363699004 |Direct device (attribute)|  = [[+id (<< 12150006 |Cannula, device (physical object)|  )]]}


Link to the misaligned concept report:

INSERT WHEN AVAILABLE

Rules for description generation: 

  1. Apply General rules for generating descriptions for templates;
  2. Apply Enhancements for the Template Language;

JIRA ticket:

Jira
serverIHTSDO JIRA
serverIdb202d822-d767-33be-b234-fec5accd5d8c
keyQI-1135

...