Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Page properties


StatusIn progress
Version

0.1


Descriptions:

Termdescription typeLanguage/acceptabilityLanguage/acceptabilityCase significance

Insertion of cannula into [body structure] (procedure)

FSNus:Pgb:Pci
Insertion of cannula into [body structure] PTus:Pgb:Pci

Example: 449181007 |Insertion of cannula into pancreatic duct (procedure)|

Concept model:

Attribute Group CardinalityAttribute cardinality

Attribute in Group Cardinality

AttributeValue
0..01..10..0


Scg expression
116680003|Is a (attribute)|



Scg expression
71388002|Procedure (procedure)|


0..1
1..1


Scg expression
260686004|Method (attribute)|



Scg expression
[imaging] <<  360037004 |Imaging - action (qualifier value)|  



0..1


Scg expression
405813007 |Procedure site - Direct (attribute)|



Scg expression
<  442083009 |Anatomical or acquired body structure (body structure)|



1..1


Scg expression
363703001 |Has intent (attribute)|



Scg expression
429892002 |Guidance intent (qualifier value)|



0..1


Scg expression
424361007 |Using substance (attribute)|



Scg expression
[contrast] << 385420005 |Contrast media (substance)|


1..1
1..1


Scg expression
260686004|Method (attribute)|



Scg expression
<< 257867005 |Insertion - action (qualifier value)|



0..1


Scg expression
405814001 |Procedure site - Indirect (attribute)|



Scg expression
[body structure] < 442083009 |Anatomical or acquired body structure (body structure)|



1..1


Scg expression
363699004 |Direct device (attribute)|



Scg expression
<< 65818007 |Stent (physical object)|



0..1


Scg expression
260507000 |Access (attribute)|



Scg expression
[access] 103388001 |Percutaneous approach - access (qualifier value)|



0..1


Scg expression
424876005 |Surgical approach (attribute)|



Scg expression
[approach] < 103379005 |Procedural approach (qualifier value)|



0..1


Scg expression
425391005 |Using access device (attribute)|



Scg expression
<< 37270008 |Endoscope, device (physical object)|


Definition status:  



Scg expression
900000000000073002|Defined (core metadata concept)|


Applies to:

Scg expression
<< 42825003 |Cannulation (procedure)|


Template language:


Scg expression
71388002 |Procedure (procedure)|  :  
[[~1..1]]{ 
[[~1..1]]  260686004 |Method (attribute)|  = [[+id (<< 257867005 |Insertion - action (qualifier value)| )]], 
[[~0..1]]  405814001 |Procedure site - Indirect (attribute)|  = [[+id (< 442083009 |Anatomical or acquired body structure (body structure)|  ) @bodyStructure]], 
[[~1..1]]  363699004 |Direct device (attribute)|  = [[+id (<< 12150006 |Cannula, device (physical object)|  )]]}


Link to the misaligned concept report:

INSERT WHEN AVAILABLE

Rules for description generation: 

  1. Apply General rules for generating descriptions for templates;
  2. Apply Enhancements for the Template Language;

JIRA ticket:

Jira
serverIHTSDO JIRA
serverIdb202d822-d767-33be-b234-fec5accd5d8c
keyQI-1135