Search



Page tree

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 5 Next »

When a new version of SNOMED CT is released this may include changes to the content of the terminology. Components may have been added, inactivated or changed as described in  11.4 VersioningAs part of the terminology maintenance process, it may be appropriate to evaluate both the  Representing Reasons for Component Inactivation and to determine appropriate alternatives.

The International Edition of SNOMED CT distributes a set of reference sets that record the reason that each inactive component was inactivated. These are referred to as "historical association" reference sets (see  4.2.3 Historical Association Reference Sets for more details). There is one historical association reference set for each type of historical association as shown in the table below.

Association reference set

Descriptions

Applies to aconceptthat is ambiguous. The targetComponent is an activeconceptthat represents one of the possible meanings of the inactiveconcept. Multiple rows are used to refer to each of the possible meanings of the ambiguousconcept.

Applies to acomponentthat has been moved to (or are pending a move to) another namespace. The targetComponent identifies the target namespace (not the newcomponent).

Applies to acomponentthat has been moved to this namespace from another namespace. The targetComponent identifies the originalcomponent Identifierin its previous namespace.

Applies to an erroneous, obsolete and otherinactive componentfor which there is a single active replacement. The targetComponent identifies the activecomponentthat replaces thiscomponent.

Applies to acomponentthat is a duplicate. The targetComponent identifies the activecomponentthat thiscomponentduplicates.

Links an inactive classificationconceptsuch as "not otherwise specified" or "otherwise specified" with the activeconceptthat was formerly its most proximal supertype.

(not used currently)

Links an inactive classificationconceptderived from ICD-9 Chapter XVI "Symptoms signs and ill-defined conditions" with the most similar activeconcept.

Applies to an inactivedescriptionwhich is inappropriate to theconcept it is directly linked to but instead should refer to theconceptreferenced by the targetComponent.

 

The following table holds example entries for the  900000000000526001 | Replaced by| reference set. With this reference set is possible to automatically identify that the inactive concept 696005 | Chronobiologic disorder| should be replaced with the concept 387605007 | Abnormal chronobiologic state| . This type of reference set is particularly useful for ensuring consistent use of SNOMED CT over time. The reference set mechanism here provides an easy and standardized way of managing changes to coding or documentation practice over time.

referencedComponentId referencedComponentId_term targetComponentId targetComponentId_term

100005

SNOMED RT Concept

138875005

SNOMED CT Concept

212002

Salmonella III arizonae 53:k:z

398450001

Salmonella IIIb 53:k:z

225005

Special care of patient with contagious disease

133895001

Care of patient with infectious disease

244003

Evans and Lloyd-Thomas syndrome

66659007

Normal variation in position

278009

Epidural injection of neurolytic substance, lumbar

17753007

Epidural injection of neurolytic solution, lumbar

558000

Other disorder of the neurohypophysis, NEC

72442006

Disorder of posterior pituitary

659001

Peptostreptococcus anaerobius

413524006

Anaerococcus tretradius

696005

Chronobiologic disorder

387605007

Abnormal chronobiologic state

700002

Salmonella III arizonae 50:z4,z23,z32:--

404619004

Salmonella IIIa 50:z4,z23,z32:-

822000

Salmonella arizonae 53:z4,z23:--

13998005

Salmonella IV 53:z4,z23:--

 

 

Feedback
  • No labels