SNOMED Documentation Search


Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Recommendation:

Were specimen source (type, source site and collection method) is conveyed in attributes other than the test name, these values should be coded using SNOMED CT.
In particular:

  • specimen type terms should be drawn from the 123038009 |Specimen| hierarchy in SNOMED CT
  • specimen source site terms should be drawn from the 123037004 |Body structure| hierarchy
  • specimen collection method terms should be drawn from the 71388002 |Procedure| hierarchy
Explanation

Notes:

Laboratory test names typically include the specimen (e.g. the LOINC "System") upon which the observation was made, but some attributes about the specimen can be carried in other parts of the information or messaging model. Where such other specimen attributes are reported as coded values, they should use SNOMED CT concepts.

...

Examples

Example 1:

...

Value Set Code NHSNSpecimenTypeCode

...

 

...

Part of the Value set for Specimen Type (PHIN-VADS CDC)

Concept Code

Preferred Concept Name

Code System Name

258414004

Adipose tissue sample

SNOMED-CT

309141004

Adrenal gland specimen

SNOMED-CT

119373006

Amniotic fluid specimen

SNOMED-CT

309479002

Artery sample

SNOMED-CT

309493009

Bile duct biopsy sample

SNOMED-CT

119341000

Bile specimen

SNOMED-CT

309491006

Biliary tract tissue sample

SNOMED-CT

119297000

Blood specimen

SNOMED-CT

119359002

Bone marrow specimen

SNOMED-CT

https://phinvads.cdc.gov/vads/ViewValueSet.action?id=6F61F377-E515-43D2-BFEB-4BF135244033#

 

 

...

Example 2: Specimen type and specimen source site in NAHLN messaging

The Specimen Type (SPM.4) field describes the precise nature of the entity that will be the source material for the observation. While every effort will be made to provide coded values for specimen types being used in NAHLN agent testing, there may be cases where a coded value specific to a particular specimen type is not immediately available. In these instances, an alternative coded value and description of the specimen may be sent in components 4-6 of the CWE data type. In some cases the precise term is not available in the coded reference system. In these situations, it is allowable to send the original text of the specimen description in the CWE.9 component

Code Block
themeConfluence
titleAn example of coded value for SPM.4

...

Code Block
themeConfluence
<SPM.4>
<CWE.1>661000009100</CWE.1>
<CWE.2>Oropharyngeal swab</CWE.2>
<CWE.3>SCT</CWE.3>
<CWE.9>OP swabs</CWE.9>
</SPM.4>

...

There is no one correct answer to precisely which detail should be provided by a pre-coordinated, more specific specimen type and which with a less specific type plus a specimen source. Many specimen/source combinations could be correctly expressed either way. The NAHLN will try to provide guidance on specific testing protocols.

Code Block
themeConfluence
titleAn example of SPM.8, used in conjunction with SPM.4

...

Code Block
themeConfluence
<SPM.4>
<CWE.1>128168004</CWE.1>
<CWE.2>Tissue specimen from liver</CWE.2>
<CWE.3>SCT</CWE.3>
</SPM.4>
<SPM.8>
<CWE.1>89255003</CWE.1>
<CWE.2>right lateral lobe of liver</CWE.2>
<CWE.3>SCT</CWE.3>
</SPM.8> 

...