Page tree

Date and time

2019-08-19 20.00 UTC

Objectives

Discussion items

See below.


ItemDescriptionOwnerNotesAction
1Welcome & apologies
  • Remember recording!



2Conflicts of interest




3Minutes from previous meetingDaniel Karlsson


4KL meetingDaniel Karlsson

There will be a meeting on Tuesday Oct 29 13.30 local time (5.30 UTC).

Items to add to the agenda.



5Susceptibility observablesDaniel Karlsson Farzaneh Ashrafi Suzanne Santamaria

Background

Draft editorial guidelines: Editorial Guidelines for Diagnostic Products Used for Susceptibility Testing

It was decided to recommend representation the physical form of the susceptibility test product, and also to use the | has presentation strenght... | attributes (as opposed to other strength attributes).

Two issues were discovered while re-reading the Inception/Elaboration document for susceptibility testing: 1. "oral form antibiotic susceptibility" exists as components in LOINC tests. 2. when other methods than culture are used, e.g. PCR or sequencing, to determine susceptibility, we might need to use another way of modeling, e.g. beta-lactamase producing ~ resistance towards beta-lactam antibiotics.

While the Susceptibility test products are needed for the mycobacteria tests (with strength-specified antibiotics), we might reconsider the approach for other cases, and use substances where products are not needed, together with a role chain | towards | o | ingredient | → | towards |.

Rob: Aren't all susceptibility tests strength-specified, even though the strength is not part of the definition?

Xavier: EUCAST breakpoint for diffusion disks : http://www.eucast.org/clinical_breakpoints/ the xls is at http://www.eucast.org/fileadmin/src/media/PDFs/EUCAST_files/Breakpoint_tables/Preliminary_v_9.0_Breakpoint_Tables_for_consultation.xlsxbreakpoint requires a definite antibio amount in the disk.

Most tests (mycobacteria tests being an exception) are based on there being a concentration gradient (e.g. disk diffusion, etest, MIC procedures) and thus not a single concentration.

2019-02-11:

An OWL ontology with Diagnostic test products and susceptibility observables is attached.

The combination substances are to be inactivated, so modeling cannot rely on use of such concepts.

2019-03-25:

An alternative version not using combination substances was presented and discussed.

Current objective

Presentation

Give recommendations on representation given two alternatives: (1) use | Susceptibility test product | as values of the | towards | attribute OR (2) use Substance together with | direct substance | = | Susceptibility test product | only when needed.

2019-04-08:

Presentation of alternatives for susceptibility observables modelling.

Has use with information models, e.g. FHIR Observation, been tested? No, but given that the observables are expression representations of LOINC content, for which there is ample experience, that is assumed not to be a problem.

Can Susceptibility test products be categorized as Pharmaceutical products, and thus be placed under 373873005 | Pharmaceutical / biologic product (product) |?

Comparison with allergy tests (skin or blood) can be explored further.

The project group voted to have a full example of using Test products as values for towards presented at next meeting (Motion: James R. Campbell , second: Raj Dash. Against: 0, Abstain: 1, For 5). Toni Morrison to be invited to discuss placement of Susceptibility test products.

At a meeting 2019-05-15 with the HoT Jim Case it was decided to again look into using Medicinal products, first checking with the Drug project.

2019-06-10:

There was agreement in the group that Medicinal Products should be used as value of the | towards | attribute for susceptibility observables. The Medicinal Products will be of the "containing only" flavor. No decision made yet about strength-specified susceptibilities.

2019-07-15:

Next steps: Update I&E document, editorial guide as well as the post-coordinated expressions in the expression refset.

2019-08-19:

A new version of the elaboration document added to this page. The new version was discussed and amended and the new version is attached.

Daniel Karlsson to update the I&E document

Farzaneh Ashrafi Suzanne Santamaria to update editorial guide and expression refset


7(Cognitive) Function observablesX

See this page.

2019-04-08:

Presentation of work done by James R. Campbell et al. at UNMC. Observables had been developed for MMSE (Mini-mental state examination). Process, scale type, and property concepts had been created in order to define the MMSE observables. Also, the section about function observables in the Observables I/E document was expanded.

The level of detail of Observables for individual instrument parts, such as the individual questions of MMSE, was discussed. Alternatively, generic observables, not specific to the instrument, could be used. UNMC preferred having specific observables.

The function observables are, according to the current pattern, defined by reference to the processes which are realized by the function, e.g. Orientation in time is realized by the function Ability to orient in time. Other observables can be defined by reference to the processes, e.g. performance of processes. Alternatively, these observables could be defined in terms of the function rather than the process.

2019-05-20:

Updates to be presented.



6

Lab observables interoperability

X

See this page.

2019-04-08:

James R. Campbell presented a request to SNOMED International to publish an OWL ontology including the LOINC expressions and expressions for any other lab terminology (e.g. NPU Terminology or the NHS pathology subset and content in SNOMED to allow classification, and comparison, of lab content.

The group was supportive of the proposal.

2019-06-10: James R. Campbell will provide a report on progress so far and a presentation help for the LOINC comittee last week.



7TUSS ObservableSuzanne Santamaria

Modeling of TUSS | Timed unsupported steady stand time (observable entity) |.

http://www.calderdaleframework.com/wordpress/wp-content/uploads/2014/04/26.PT36-TUSS.pdf

https://www.physiotherapyjournal.com/article/S0031-9406(05)65775-6/pdf

2019-08-19:

A solution based on the process observable pattern was presented. The primitive stated parents were discussed and 282316001 | Ability to stand alone (observable entity) | or 363838007 | Balance observable (observable entity) | might be plausible candidates depending on how "ability" is to be interpreted.


Applying the function observable seems possible but difference (| has realization| in stead of | characterizes |) is small. It should be investigated if both patterns are really needed.


8Nutrition observables
As a result of collaboration around the eNCPT nutrition terminology quite a few nutrition observables will likely be added to SNOMED CT over the next releases. Current examples include nutrition substance intake, e.g.:
  • Estimated protein intake in 24 hours (observable entity)
  • Measured protein intake from oral nutrition in 24 hours (observable entity)
  • Measured protein intake from enteral nutrition in 24 hours (observable entity)

As (almost) seen, these are rate observables (mass/time quantity) and those have previously been modeled as process observables. The examples highlight an issue with process observables in that the processes themselves do not have a concept model, but only those parts deemed relevant to observables. E.g. the administration route here cannot be represented using the model.

2019-07-15:

Sarah Harry compare with excretion observables in laboratory medicin, in what sens are they same or different.

A page for discussion: Nutrition observables

2019-08-19:

Sarah Harry presented a comparison of "output" observables (slides attached).

Possibly, "output" or "input" (e.g. intake) observables could be represented either using a process observable pattern (using process observable attributes such as | process output |) or a quality observable pattern (using quality observable attributes such as | inheres in | etc.). In order to determine if both patterns are needed or not, a list of example observables from SNOMED CT, LOINC and eNCPT should be collected and discussed.

SNOMED International is working to model nutrition observables together with dietitians' organizations. Results and questions will be posted on the Nutrition observables sub page.

  • Daniel Karlsson to collect a list of "input/output" observables from SNOMED, LOINC, and eNCPT.
  • Penni Hernandez to provide input from the nutrition observables work

9Next meeting

Next meeting is 2019-09-16 20.00UTC



10AOB




Meeting Files

  File Modified
Microsoft Word Document CTP Project Elaboration Susceptibility_2019-08-14.docx 2019-Aug-15 by Daniel Karlsson
Microsoft Powerpoint Presentation Intake-Output_observables_SH.pptx 2019-Aug-19 by Daniel Karlsson
Microsoft Word Document CTP Project Elaboration Susceptibility_2019-08-20.docx 2019-Aug-20 by Daniel Karlsson
PNG File image2019-8-20_10-39-47.png 2019-Aug-20 by Daniel Karlsson

Recordings

https://snomed.zoom.us/recording/share/sD1Tcpb6ALJprzRJXsgvtc_oCWF5eRhnQ4qn2QLi4v2wIumekTziMw

More Zoom details

Topic: Observables meeting

Time: this is a recurring meeting Meet anytime

Join from PC, Mac, Linux, iOS or Android:
https://snomed.zoom.us/j/992630241

Or Telephone:
Dial:
+46 (0) 8 4468 2488 (SE Toll)
+61 (0) 2 8015 2088 (AU Toll)
+32 (0) 2 588 4188 (BE Toll)
+1 647 558 0588 (CA Toll)
+56 41 256 0288 (CL Toll)
+420 2 2888 2388 (CZ Toll)
+45 89 88 37 88 (DK Toll)
+372 880 1188 (EE Toll)
+852 5808 6088 (HK Toll)
+353 (0) 1 691 7488 (IE Toll)
+972 (0) 3 978 6688 (IL Toll)
+370 5214 1488 (LT Toll)
+60 3 9212 1727 (MY Toll)
+356 2778 1288 (MT Toll)
+31 (0) 20 241 0288 (NL Toll)
+64 (0) 9 801 1188 (NZ Toll)
+64 (0) 4 831 8959 (NZ Toll)
+47 2396 0588 (NO Toll)
+48 22 307 3488 (PL Toll)
+351 308 804 188 (PT Toll)
+65 3158 7288 (SG Toll)
+421 233 056 888 (SK Toll)
+386 1888 8788 (SI Toll)
+34 91 198 0188 (ES Toll)
+41 (0) 31 528 0988 (CH Toll)
+44 (0) 20 3695 0088 (GB Toll)
+1 408 638 0968 (US Toll)
+1 646 876 9923 (US Toll)
+1 669 900 6833 (US Toll)

Meeting ID: 992 630 241

International numbers available: https://snomed.zoom.us/zoomconference?m=AQWV2VqAIGYWMcMapl9CoYjsaj1TVS7K